Specification of the Blocked Chute Switch
AMD 120 DIP BLOCKED CHUTE / LEVEL SWITCH
For use on free flowing materials at atmospheric pressure.The AMD 120 DIP can eliminate spillage and expensive cleanups in cases of Bin overflow or conveying blockages.
Dependability and low cost are synonymous with the AMD 120 DIP.
For best results and sensitivity, connect with a 20mm conduit to allow the dissipation of displaced air in the housing caused by the movement of the diaphragm.
Specification:
Certified IP 65 T6 DIP AUS Ex 3677
Aluminium Casting
Faceflange is 304 Stainless Steel
Fully Gasketed - it is both weather
and dust proof
Hard wearing diaphragm
Temperature to 110 Deg. C.
Two wire circuit N/O or N/C SPDT.
Voltage 12V to 240V. Rated 2 Amps
Sensitivity Adjustment.
Electrical Conduit Entry - 20mm.
Mounting is 6 x 6mm on 154 PCD
Bin cutout is 110 mm.
Shipping weight is 1.25 kgs.

AMD-WMF Mounting Flange

MAT,L 4mm PLATE MS ZINC PLATED
SUPPLIED WITH 6 OFF M6 X 30 SET SCREWS ZINC PLATED
INSTALLATION
CUT HOLE Ø 130 IN CHUTE AND WELD WMF FLANGE
IN PLACE THEN MOUNT amd 120 SWITCH